[[computemodul4_temperature_test]]

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
computemodul4_temperature_test [2021/05/03 00:50]
wf68spef
computemodul4_temperature_test [2021/05/17 01:00] (current)
wf68spef [Test 3 - Wifi]
Line 16: Line 16:
   * PI4 Internal CPU Thermometer   * PI4 Internal CPU Thermometer
   * Multimeter: AM-550-EU PTC Temperature for Wifi Temperature Measurements   * Multimeter: AM-550-EU PTC Temperature for Wifi Temperature Measurements
 +      * The temperature of the wifi module by placing the ptc at the heatsink of the wifi module
 +      * Not highly accurate, but should give a indication
 +Lab Power source
 +  * Quatpower LN-3003 ​
  
 ====== Software ====== ====== Software ======
  
-==== Reduced ​power usage by disabling various ​CM4 modules ​====+==== Reduce ​power usage of CM4 ====
  
 **no bluetooth** **no bluetooth**
Line 49: Line 53:
   * config.txt   * config.txt
   * dtparam=audio=off   * dtparam=audio=off
 +
 +**no USB**
 +  * disabled by default @ CM4 for powersaving
 +  * https://​www.jeffgeerling.com/​blog/​2020/​usb-20-ports-not-working-on-compute-module-4-check-your-overlays
  
 ==== Testsoftware ====  ==== Testsoftware ==== 
Line 114: Line 122:
 ^ Testmode ​     ^ Time (h) ^ Power usage (Wh)  ^ Power usage (W) ^ CPU Temp (°C) ^ WIFI Temp (°C) ^ ^ Testmode ​     ^ Time (h) ^ Power usage (Wh)  ^ Power usage (W) ^ CPU Temp (°C) ^ WIFI Temp (°C) ^
 | IDLE          |  0:00    |   ​- ​          ​| ​  ​1.7 ​        ​| ​ 43.8           ​| ​ 30           | | IDLE          |  0:00    |   ​- ​          ​| ​  ​1.7 ​        ​| ​ 43.8           ​| ​ 30           |
-| use 2 cameras |  0:00    |   ​- ​          ​| ​  ​2.4 ​        ​| ​ 43.8           | 30           | +| use 2 cameras |  0:00    |   ​- ​          ​| ​  ​2.4 ​        ​| ​ 43.8           ​| ​ 30           | 
-| WIFI          |  0:00    |   ​- ​          ​| ​  ​2.65 ​        ​| ​ 43.8          | 30           |+| WIFI          |  0:00    |   ​- ​          ​| ​  ​2.65 ​        ​| ​ 43.8          |  30           |
 | use 2 cameras + WIFI |  0:00    |   ​4.83 ​      ​| ​  ​3.2 ​          ​| ​ 43.8           ​| ​  ​30 ​          ​| ​ | use 2 cameras + WIFI |  0:00    |   ​4.83 ​      ​| ​  ​3.2 ​          ​| ​ 43.8           ​| ​  ​30 ​          ​| ​
 | use 2 cameras + WIFI |  0:15    |   ​5.666 ​      ​| ​  ​3.2 ​          ​| ​ 52.0           ​| ​  ​48 ​          ​| ​ | use 2 cameras + WIFI |  0:15    |   ​5.666 ​      ​| ​  ​3.2 ​          ​| ​ 52.0           ​| ​  ​48 ​          ​| ​
Line 121: Line 129:
  
 Using the power usage in Wh a **mean power of ~3.38W** is needed when using 2 cameras + wifibroadcast. Using the power usage in Wh a **mean power of ~3.38W** is needed when using 2 cameras + wifibroadcast.
 +
 +==== Test 3 - Wifi ==== 
 +
 +As it turned out that the radio power amplifier was not connected in test #2, i reran the test. Power is provided by the laboratory power source @ 12.3V + DCDC Converter @ 5V for the cm4 board. ​
 +
 +**NOTE:** The sligtly incread Idle power usage is due to the additional DCDC converter, and the powermeasurement BEFORE this converter.
 +
 +^ Testmode ​ ^ Time (h) ^ Power usage (W) ^ CPU Temp (°C) ^ WIFI Temp (°C) ^
 +| IDLE |  0:00    | 2.3      |  34.5          |  27           |
 +| WIFI |  0:01    | 5.78     ​| ​ 36.5          |  29           |
 +| WIFI |  0:11    | 5.78     ​| ​ 46.7           ​| ​  ​58 ​          ​| ​
 +| WIFI |  0:21    | 5.78     ​| ​ 51.0           ​| ​  ​62 ​          ​| ​
 +| WIFI |  0:30    | 5.78     ​| ​ 51.0           ​| ​  ​63 ​          ​| ​
 +
 +
 +
  
  
  • computemodul4_temperature_test.1619995800.txt.gz
  • Last modified: 2021/05/03 00:50
  • by wf68spef